双组份打胶机机头不在原位怎么调?
双组份打胶机机头不在原位怎么调?
济南双组份打胶机厂家提醒您,可以先连接电源,然后在控制面板上操作,然后在做调整。具体操作流程是:
How to adjust if the head of two-component sealant dispenser is not in place? The manufacturer of Jinan two-component sealant dispenser reminds you that you can connect the power supply first, then operate it on the control panel, and then make adjustments. The specific operation process is as follows:
1、放在一个平整干净的平面上,连接电源和气源,两者确认接通之后就开始进行操作。
1. Put it on a flat and clean surface, connect the power supply and air supply, and start the operation after they are confirmed to be connected.
2、打胶机中间会有一个混胶过程,在供胶机上面混胶完毕之后,需要在电子显示屏上控制面板上进行选择行走设置。在机头停止时,打开机头上面B胶阀门,接着在控制面板上找到Esc键返回主界面,然后F2状态设置,在打开界面后按K3键供胶开始,当胶嘴中完全混合的胶流出按K4键结束供。
2. There will be a glue mixing process in the middle of the glue feeder. After the glue is mixed on the glue feeder, you need to select the walking setting on the control panel on the electronic display screen. When the handpiece stops, open the B glue valve on the handpiece, find the Esc key on the control panel to return to the main interface, and then set the F2 status. After opening the interface, press the K3 key to start glue supply, and press the K4 key to end glue supply when the glue completely mixed in the nozzle flows out.
3、需要记住的是工作结束之后或者在较长时间不工作时,需要冲洗混胶装置,防止供胶管的堵塞,影响未来使用效果。
3. It should be remembered that after the work is completed or when the machine is not working for a long time, the rubber mixing device needs to be flushed to prevent the rubber supply pipe from being blocked and affecting the future use effect.
4、调整环节,吸盘调整,涂胶机吸盘与旋转台的高度调整合适。
4. The adjustment link, suction cup adjustment, and the height adjustment of the glue applicator suction cup and the rotary table are appropriate.
5、气动开关、胶嘴、探针调整,将事先合好的中空玻璃放在旋转台上,靠近涂胶机工作面,然后中空玻璃推到定位上,调整胶嘴与玻璃的高度,使出胶嘴的出胶口语铝槽在同一个水平线上,胶嘴与玻璃之间的顶力合适,铝槽深度检测探针与出胶口线在统一水平线上。
5. Adjust the pneumatic switch, rubber nozzle and probe. Put the previously closed insulating glass on the rotary table close to the working face of the glue applicator, and then push the insulating glass to the position. Adjust the height of the rubber nozzle and the glass, so that the center of the aluminum groove at the rubber outlet of the rubber nozzle is on the same horizontal line, the jacking force between the rubber nozzle and the glass is appropriate, and the aluminum groove depth detection probe and the center line of the rubber outlet are on the same horizontal line.
6、启动开关机头的非常前端的光开关与玻璃之间的检测距离1.5~2mm。在控制面板上选择状态设置,打开状态设置后选择吸盘开K5键,此时机头会往前移动,如果不往前移动则检查并调整启动开关的检测距离。
6. The detection distance between the optical switch at the very front end of the starting switch head and the glass is 1.5~2mm. Select the status setting on the control panel. After opening the status setting, select the K5 key of the suction cup. At this time, the machine head will move forward. If it does not move forward, check and adjust the detection distance of the start switch.
This is the way to adjust the two-component sealant dispenser head when it is not in place. Do you have anything to ask about it? Welcome to our website http://www.jntiannuo.com Get to know more!
上一篇:打胶机呈现花胶以及打胶不丰满的原因